
Chapter 10. JS23 and JS43 power management using EnergyScale technology 405
-pme: power management and capping enabling for blades (off, on).
Note: the
blade must be powered on before enabling capping.
-ps: power saver mode for blades (off, on). Note: the blade must be
powered
on before enabling power saver mode.
-pt: power trending data (1, 6, 12, or 24 hours)
-tt: thermal trending data (1, 6, 12, or 24 hours)
Example 10-2 shows the fuelg command used from the system> prompt with no
flags to display the BladeCenter Power Domain information.
Example 10-2 The fuelg command used to display BladeCenter Power Domain
system> fuelg
Note: All power values are displayed in Watts.
Total DC Power Available: 2900
Total AC Power In Use: 807
Total Thermal Output: 2753 BTU/hour
Power Domain
--------------
Status: Power domain status is good.
Modules:
Bay 1: 1450
Bay 2: 1450
Bay 3: 1450
Bay 4: 1450
Power Management Policy: AC Power Source Redundancy
Power in Use: 769
Total Power: 2900
Allocated Power (Max): 1346
Remaining Power: 1554
Power Service: 220 VAC
-am off
-int 10
From the AMM system> prompt use the env command to set the specified blade
as the persistent target for commands during the current session. Example 10-3
shows the environment being set to blade slot 4. Note the prompt change.
Comentários a estes Manuais