E-TECH ET8 (V4) CONTROL PANEL INSTALLER MANUAL
RADIO DEVICES – OPERATION
ALARM: Any E-Tech Radio Device can operate on any zone 18 as programmed by
P01E~P08E. The hardwired zones 18 continue to operate in parallel.
Radio Keys can also operate on radio zones 1~8 for special purposes, but they should
normally be used as Radio Codes.
KEYSWITCH INPUT: A Radio Device programmed to Zone 8 will still work as an alarm even
if the Zone 8 input operation has been changed to Keyswitch operation. The P60E 2E and
3E options only affect the Zone 8 terminal inputs.
VIBRATION: Radio device zone signals IGNORE the P30EP38E vibration sensor settings.
TAMPER REPORT: Radio Device Tamper operation depends on the Armed State of the
control panel.
RADIO TAMPER: causes the keypad to continuously beep and also to flash the RADIO,
TAMPER and the ZONE (identifying the detector) lights. Pressing any key on the keypad or
sending a TAMPER RESTORE will clear this warning.
LOW BATTERY REPORT: A low battery gives 10 beeps and flashes the RADIO & the
BATTERY light. The ZONE light identifying the radio device is also ON. The flashing lights
stop when any key on the keypad is pressed or a detector code with no low battery is
received. Low Battery generates HISTORY and DIALLER reports ONCE only (until the low
battery is fixed and a restore report is received).
SUPERVISION: If a zone has the P65E option ON and a radio code has been programmed
for that zone, then the supervision is active. This means that the radio detector does not
need to have its SUPER enabled (via header link) for the SUPERVISED timeout to occur.
(Useful as an inactivity alarm). A zone supervision failure always flashes the identifying
ZONE light and the RADIO light.
RADIO KEY
PENDANT
100-665
RADIO KEY
3 BUTTON
100-664
RADIO PIR
100-663
RADIO
REED SWITCH
100-662
RADIO SMOKE
DETECTOR
100-203
SIGNAL
TYPE
E-TECH RADIO DEVICES
Signal types transmitted
ALARM
ON button
OFF button yes yes yes
yes yes yes yes yes
yes yes
yes yes yes
ON button yes yes yes
RESTORAL
LOWBA TT
TAMPER
SUPERVISION
O
F
F
O
N
P
A
N
I
C
RADIO SUPERVISION
The purpose of Radio Supervision is to verify the correct operation of E-Tech
Radio PIRs. The Supervision signal from the Radio PIR tells the panel that the
device has not been removed from radio range and is in working order.
Non-SUPERVISION Radio PIRs can also be programmed and used with the ET8
SUPERVISION TIMERS.
A non-SUPERVISION enabled Radio PIR will transmit signals to the ET8 only
when it has detected an event. Obviously, there is no guaranteed signal period.
In either case, when the allowed time limit is exceeded then a WARNING is first
given (if programmed by P66E 3E), and then after 1 minute, the programmed
RADIO SUPERVISION ALERTS are generated by the ET8.
NOTE: Manually Excluding a Supervised Zone will also disable Radio
Supervision for that zone.